How to Read Steam Generator Specifications?

Steam Generator selection should not be based only on kW. Power, voltage, phase, current, wire size, suitable room volume, unit size, and site conditions should be reviewed together.

Power rating Voltage and phase Wire size Unit size

Key Summary

HENGJHU Steam Generators are mainly available in even power ratings: 6kW, 8kW, 10kW, 12kW, 14kW, and 16kW.

Selection should also review power conditions, installation position, service opening, steam piping, and control panel layout.

Power is not the only factor Room height, sealing, pipe length, and use pattern can affect the result.
Power supply affects wire size The same kW rating may require different current and wire size under different power supplies.
Size affects service access The unit must not only fit the space, but also allow piping and future service.

Specifications are more than kW

A Steam Generator is a high-power device. Even when the room size seems suitable, power conditions, unit location, steam piping, and service access may still limit installation.

Even power ratings 6kW, 8kW, 10kW, 12kW, 14kW, and 16kW.
Series reference only Unit dimensions may vary by brand and model.

1. HENGJHU Steam Generators mainly use even power ratings

HENGJHU Steam Generators are mainly available in 6kW, 8kW, 10kW, 12kW, 14kW, and 16kW.

Higher power usually supports a larger steam room, but power is not the only selection factor.

Room conditions

Room volume, ceiling height, door sealing, and wall or floor conditions affect performance.

Power conditions

Voltage, phase, panel capacity, dedicated circuit, and wire size must match the unit.

Installation conditions

Unit location, service opening, steam pipe length, and pipe diameter should be checked.

Power rating is a starting point, not a replacement for site condition review.

2. 6kW, 8kW, and 10kW specifications

6kW, 8kW, and 10kW are often reviewed for residential or smaller steam rooms.

Model Power Power Supply Current Wire Size Suitable Space
HG-206 6kW 220V single-phase 28A 8mm² 3.5m³
HG-208 8kW 220V single-phase 37A 14mm² 7m³
HG-210 10kW 220V single-phase 46A 14mm² 8.25m³
HG-306 6kW 220V three-phase 16A 5.5mm² 3.5m³
HG-308 8kW 220V three-phase 21A 5.5mm² 7m³
HG-310 10kW 220V three-phase 27A 8mm² 8.25m³
HG-3306 6kW 380V three-phase 10A 5.5mm² 3.5m³
HG-3308 8kW 380V three-phase 13A 5.5mm² 7m³
HG-3310 10kW 380V three-phase 16A 5.5mm² 8.25m³

The same 6kW, 8kW, or 10kW power rating may have different current and wire size requirements depending on the power supply.

For example, 10kW is 46A with 14mm² wire under 220V single-phase, 27A with 8mm² wire under 220V three-phase, and 16A with 5.5mm² wire under 380V three-phase.

Do not select only by kW. Voltage, phase, wire size, breaker, and dedicated circuit must be checked together.

3. 12kW, 14kW, and 16kW high-power specifications

For larger steam rooms or higher use needs, 12kW and above may be reviewed.

Model Power Power Supply Current Wire Size Suitable Space
HG-312 12kW 220V three-phase 32A 8mm² 14m³
HG-314 14kW 220V three-phase 37A 8mm² 16m³
HG-316 16kW 220V three-phase 43A 14mm² 18m³
HG-3312 12kW 380V three-phase 19A 5.5mm² 14m³
HG-3314 14kW 380V three-phase 22A 5.5mm² 16m³
HG-3316 16kW 380V three-phase 25A 8mm² 18m³

For 12kW and above, power conditions should be checked carefully. Current, wire size, breaker, panel capacity, and dedicated circuit all need review.

For commercial spaces, guesthouses, clubs, hotels, or high-use spaces, confirm whether the site has suitable three-phase power conditions.

4. Main unit dimensions should also be checked

Unit size is also important during planning.

The following dimensions are for HENGJHU Steam Generator series reference. Dimensions may vary by brand and model.

Power Main Unit Dimensions
6kW, 8kW L 45cm × W 15cm × H 33cm
10kW L 45cm × W 15cm × H 37cm
12kW, 14kW, 16kW L 45cm × W 25cm × H 37cm
1
Stable installation The unit should be installed level and securely supported.
2
Enough piping space Water inlet, steam outlet, power cable, and drain valve connection space should be reserved.
3
Service opening and access The unit should not only fit; it should also be serviceable later.

5. Suitable space is an initial reference, not the only decision factor

The suitable space in the specification table can be used as an initial reference.

6kW

About 3.5m³, usually reviewed for smaller steam rooms.

8kW and 10kW

8kW is about 7m³, and 10kW is about 8.25m³.

12kW and above

12kW is about 14m³, 14kW about 16m³, and 16kW about 18m³.

Actual planning should not rely only on volume. Ceiling height, door sealing, pipe length, steam outlet position, and use frequency can also affect the result.

Room height, door sealing, wall and floor materials, user number, use frequency, steam outlet position, pipe length, and floor slope may all affect the steam room experience.

6. Steam room height affects performance

Steam room height can affect the user experience.

In general planning, a steam room height within 220cm is easier to reach the desired feeling. If the room is too high, steam and warm air may gather near the top.

Power review

Higher rooms need a closer review of room volume and heat distribution.

Preheating time

A higher room may need longer preheating time.

User position

Check whether seated or standing users can feel the steam properly.

Before selecting generator power, confirm the length, width, and height of the steam room.

7. Voltage and phase affect current and wire size

The same power rating may have different current under different power supply conditions.

Example: 8kW

220V single-phase: 37A, 14mm² wire. 220V three-phase: 21A, 5.5mm² wire. 380V three-phase: 13A, 5.5mm² wire.

This means Steam Generator planning should confirm kW, voltage, phase, and power distribution together.

1
Confirm voltage and phase Check whether the site has 220V single-phase, 220V three-phase, or 380V three-phase.
2
Confirm dedicated circuit The Steam Generator must use a dedicated circuit and should not share power with other appliances.
3
Confirm wire and protection Wire size, breaker, leakage protection, and grounding should follow equipment needs.

8. How to initially review 6kW, 8kW, and 10kW

For residential or smaller steam rooms, 6kW, 8kW, and 10kW are often reviewed first.

6kW

About 3.5m³, suitable as an initial direction for small steam rooms.

8kW

About 7m³, but room height and sealing still need review.

10kW

About 8.25m³, suitable as a reference for spaces near 8m³.

If the space is high, poorly sealed, has large door gaps, or has a long steam pipe, the selection may need to be reviewed again.

9. 12kW, 14kW, and 16kW require closer site review

12kW, 14kW, and 16kW are larger power configurations. They should not be selected by suitable space alone.

Power capacity

Three-phase power, panel capacity, wire size, and breaker should be confirmed.

Unit size

12kW, 14kW, and 16kW units are 25cm wide, so installation and service space matter.

Steam pipe diameter

Higher power may require more attention to pipe diameter, outlet sound, and pipe pressure.

For ceiling, cabinet, or equipment cabinet installation, check space, service opening, and service access.

10. Specifications still need to return to site conditions

Specifications help with initial selection, but they cannot replace site review.

1
Room conditions Confirm room length, width, height, seating, and door sealing.
2
Power and installation conditions Confirm voltage, phase, main panel, dedicated circuit, unit location, and service opening.
3
Piping and control conditions Confirm cold water supply, steam pipe, control panel location, and signal wire route.
Steam Generator specifications should always be reviewed together with site construction conditions.

Conclusion: understanding specifications helps selection go beyond kW

Steam Generator selection should not only ask how many kW the room needs.

A better review includes power rating, power supply, current, wire size, suitable room volume, unit size, and site installation conditions.

HENGJHU Steam Generators are mainly available in 6kW, 8kW, 10kW, 12kW, 14kW, and 16kW. Smaller to mid-range models can support residential and smaller spaces, while higher power models are for larger steam rooms or higher use needs.

Whatever power is selected, site conditions must be checked. Room size, power conditions, piping, unit size, service opening, and control panel location should work together.

Not sure which Steam Generator specification to choose?

Contact HENGJHU with your steam room size, site power conditions, unit location, service opening, steam pipe layout, and use needs.

We can help review the suitable specification direction.